Image 1
Image 2
Image 3
New Design. More Content. Relaunch kabeltrax.de

ME 0320

with unscrewable plastic stays

Picture: ME 0950

Stay variants

Stay variant RE

unscrewable stays

Opening options:
Outside/Inside: simply by turning

Stay arrangement: Stays mounted on every chain link.

Dimensions and intrinsic chain weight

Type

hi mm

Bi mm

Bk mm

Intrinsic chain weight (kg/m)

ME 0320 RE

19

25

36

0.46

ME 0320 RE

19

29

40

0.47

ME 0320 RE

19

33

44

0.48

ME 0320 RE

19

37

48

0.50

ME 0320 RE

19

41

52

0.51

ME 0320 RE

19

45

56

0.52

ME 0320 RE

19

49

60

0.54

ME 0320 RE

19

53

64

0.55

ME 0320 RE

19

57

68

0.56

ME 0320 RE

19

61

72

0.57

ME 0320 RE

19

65

76

0.58

ME 0320 RE

19

69

80

0.59

ME 0320 RE

19

73

84

0.60

ME 0320 RE

19

77

88

0.62

ME 0320 RE

19

81

92

0.63

ME 0320 RE

19

85

96

0.64

ME 0320 RE

19

89

100

0.66

ME 0320 RE

19

93

104

0.67

ME 0320 RE

19

97

108

0.68

ME 0320 RE

19

101

112

0.69

ME 0320 RE

19

105

116

0.71

ME 0320 RE

19

109

120

0.72

ME 0320 RE

19

113

124

0.73

ME 0320 RE

19

117

128

0.74

ME 0320 RE

19

121

132

0.76

ME 0320 RE

19

125

136

0.77

ME 0320 RE

19

129

140

0.78

ME 0320 RE

19

133

144

0.80

ME 0320 RE

19

137

148

0.81

ME 0320 RE

19

141

152

0.82

ME 0320 RE

19

145

156

0.84

ME 0320 RE

19

149

160

0.85

Bend radius and pitch

Bend radii KR (mm)

37

47

77

100

200


Pitch t = 32 mm

Load diagram

for unsupported length Lf depending on the additional load

Unsupported length Lf

In the case of longer travel lengths,sag of the cable carriers is technically permissible depending on the application.In a gliding arrangement, even longer  travel lengths are possible.

We are at your service to advise onthese applications.

Connection variants

Connection point
M – Driver
F – Fixed point

Connection type
A – Threaded joint outside (standard)
I – Threaded joint inside
H – Threaded joint, rotated through 90° to the outside
K – Threaded joint, rotated through 90° to the inside

In the standard version, the connectors are mounted with the threaded joint outwards (FA/MA). The connection type can subsequently be altered simplyby varying the connectors.

Questionnaire

Contact us to find a solution to your individual application problem.

Your contact person

© 2012 TSUBAKI KABELSCHLEPP GmbH