MC0950 RS

Aluminum stay RS – frame stay narrow

mc0950-rs_start.png

Properties

  • Extremely quick to open and close
  • Aluminum profile bars for light to medium loads. Assembly without screws.
  • Available customized in 1 mm grid.
  • Outside/inside: release by turning by 90°.
test
Stay arrangement on every 2<sup>nd</sup> chain link

Stay arrangement on every 2nd chain link, standard (HS: half-stayed)

Stay arrangement on every chain link

Stay arrangement on each chain link (VS: fully-stayed)

Inner width (B<sub>i</sub>) in 1 mm increments
Bi 75 – 400 mm in 1 mm width sections

Dimensions

Dimensions
Important information

The maximum cable diameter strongly depends on the bending radius and the desired cable type. Please contact us.

Important information

For rough environmental conditions, we recommend the use of OFFROAD glide shoes with 80 % higher wear volume.

Calculating the cable carrier length
Cable carrier length LK: LK ≈ LS/2 + LB
Cable carrier length Lk rounded to pitch t
t
[mm]
hi
[mm]
hG
[mm]
hG'
[mm]
hG' Offroad
[mm]
Bi
[mm] *
Bk
[mm]
BEF
[mm]
qk
[kg/m]
95588083.58675 – 400Bi + 39Bi + 392.93 – 4.71
* in 1 mm width sections
KR
[mm]
140170200260290320380
Order example
Order code

MC0950

400

RS

200

2850

HS

Our technical support can provide help for gliding arrangements: technik@kabelschlepp.de

Inner distribution

Divider systems

As a standard, the divider system is mounted on each crossbar – for stay mounting on every 2nd chain link (HS).
As a standard, dividers and the complete divider system (dividers with height separations) can be moved in the cross section (version A).

For applications with lateral acceleration and rotated by 90°, the dividers can be attached by simply clipping on a socket (available as an accessory).
This socket additionally acts as a spacer between the dividers and is available in a 1 mm grid between 3 – 50 mm, as well as 16.5 and 21.5 mm (Version B).

Divider system TS0

without height separation
Vers.
aT min
[mm]
ax min
[mm]
ac min
[mm]
nT min
A4.514102

The dividers can be moved in the cross section.

Divider system TS0

Divider system TS1

with continuous height separation
Vers.
aT min
[mm]
aT max
[mm]
ax min
[mm]
ac min
[mm]
nT min
A4.52514102

The dividers can be moved in the cross section.

Divider system TS1

Divider system TS2

with partial height separation
Vers.
aT min
[mm]
ax min
[mm]
ac min
[mm]
nT min
A4.523192

With grid distribution (1 mm grid). The dividers are attached by the height separation, the grid can be moved in the cross section.

Sliding dividers are optionally available (thickness of divider = 4 mm).

Divider system TS2
Important information

Please note that the real dimensions may deviate slightly from the values indicated here.

Divider system TS3

with height separation consisting of plastic partitions

As a standard, the divider version A is used for vertical partitioning within the cable carrier. The complete divider system can be moved within the cross section.

Divider version A

End divider

Vers.
aT min
[mm]
ax min
[mm]
ac min
[mm]
nT min
A6/2*14102

* for End divider

The dividers are fixed by the partitions, the complete divider system is movable in the cross section.

Divider system TS3
Divider system TS3
ax (center distance of dividers) [mm]
ac (nominal width of inner chamber) [mm]
16
8
18
10
23
15
28
20
32
24
33
25
38
30
43
35
48
40
58
50
64
56
68
60
78
70
80
72
88
80
96
88
112
104
128
120
144
136
160
152
176
168
192
184
208
200

When using partitions with ax > 49 mm we recommended an additional preferential central support. 

Order example
Order code

TS3

A

3

K1

K4

34

38

VR1

VR3

Please state the designation of the divider system (TS0, TS1,...), version and number of dividers per cross section [nT ]. In addition, please also enter the chambers [K] from left to right, as well as the assembly distances [aT/ax] (as seen from the driver).

If using divider systems with height separation (TS1 – TS3), please also state the positions [e.g. VD23] viewed from the left driver belt. You are welcome to add a sketch to your order.

End connectors

M0950 End Connector UMB
M0950 End Connector UMB
Important information

Recommended tightening torque: 27 Nm for cheese-head screws ISO 4762 - M8 - 8.8

M0950 End Connector UMB
Connection point

F – fixed point
M – driver

Connection type

U – universal mounting bracket

M0950 End Connector
M0950 End Connector
M0950 End ConnectorM0950 End Connector
Connection point

– fixed point
– driver

Connection type

A – threaded joint outside (standard)
I – threaded joint inside

Connection surface

– connection surface inside
– connection surface outside

Order example
Order code

Plastic/steel

F

A

U

UMB

M

U

 

End connector

Plastic/steel

UMB

Connection point

F

M

Connection type

A

U

Connection surface

U

Important information

We recommend the use of strain reliefs at the driver and fixed point.

Downloads

Matching with

Cables for cable carriers – TRAXLINE®

Reliable, robust with high availability. Your benefit from many years of experience combined with ongoing optimization, proven in tests and praxis. TRAXLINE® cables stand for competent system-supply with worldwide on-site service.

to TRAXLINE®

Ready-to-connect cable carrier systems – TOTALTRAX®

From pre-assembled cables to complex, ready-to-connect systems, from lot size 1 to series – worldwide thousands of KABELSCHLEPP systems are reliably in use. The benefits of TOTALTRAX® systems are obvious: just one person of contact, one order number, delivery just-in-time to your production facility, shortest downtimes thanks to plug&play installation.

to TOTALTRAX®

Accessories

Reliable unrolling and optimum gliding for long travel lengths

to Support trays
to Guide channels

For optimum placement with dynamic use of cables

to Strain relief devices

Services

Product Configurator
Product Configurator
Close

Product Configurator

  • Efficient, quick and complete configuration ­ the result is your individual product with an excellent price-performance ratio
  • Product configurator OnlineEngineer + suitable CAD model from CADenas without having to exit the portal
CADenas
CADenas
Close

CADenas

  • Decrease your engineering times
  • Accelerate your design processes
  • Configure with original data directly from the manufacturer
  • Providing 3D component models in a variety of CAD formats
Glossary
Glossary
Close

Glossary

Cable Carriers – Overview of general abbreviations and pictographs

Technical information
Technical information
Close

Technical information

Configuration guidelines:

  • Selecting a suitable cable carrier
  • Placement guidelines for cables and hoses
  • Installation variants